What does each dot represent?
Each dot represents two consecutive accepted intervals: RR n on the horizontal axis and RR n plus one on the vertical axis.
An HRV Poincaré plot places each accepted RR interval on the horizontal axis and the next interval on the vertical axis. The point cloud shows how consecutive beat intervals relate to one another. Its width, length, density and outliers can reveal data patterns, but the plot cannot diagnose a condition by itself.
A point at 900 milliseconds on the horizontal axis and 940 milliseconds on the vertical axis means one interval lasted 900 milliseconds and the following interval lasted 940 milliseconds. The next plotted point uses that 940-millisecond interval on the horizontal axis and the subsequent interval on the vertical axis.
The diagonal line from lower left to upper right is the line of identity, where two consecutive intervals are equal. Points above it represent a following interval that is longer than the preceding one. Points below it represent a following interval that is shorter.
SD1 describes dispersion perpendicular to the identity line and represents short-term point-to-point variation. For a standard lag-one plot using the same accepted intervals and conventional sample calculations, SD1 is mathematically related to RMSSD. SD2 describes dispersion along the identity line and reflects longer variation within the analyzed recording. Both values depend on the recording window and preprocessing.
A compact cloud means consecutive intervals changed less within that sample. A wider cloud means greater short-term variation. Slow, regular oscillation can stretch the cloud, while clusters, branches or isolated points may reflect changing physiology, nonstationary data, artifacts or rhythm irregularity. Similar-looking plots can have different causes, so shape labels should remain descriptive rather than diagnostic.
An isolated point may be produced by movement, weak electrode contact, a missed beat, an extra detection or a real irregular interval. A single bad interval often creates two unusual points because it is paired once with the interval before it and once with the interval after it. Compare the plot with the RR time series and the device signal before excluding anything.
Each dot represents two consecutive accepted intervals: RR n on the horizontal axis and RR n plus one on the vertical axis.
SD1 measures dispersion perpendicular to the line of identity and summarizes short-term beat-to-beat variation in the analyzed intervals.
SD2 measures dispersion along the line of identity and summarizes longer variation within the selected recording.
One unusual interval participates in two pairs, so a single missed or extra detection can generate two points away from the main cloud.
A plot can show irregular patterns, but it cannot confirm atrial fibrillation or identify the cause. Diagnosis requires an appropriate clinical rhythm assessment.
They are closely related for a conventional lag-one plot using the same accepted intervals and calculation conventions, but they are not interchangeable labels. Report the method used.
Disclaimer
hrv.live, rmssd.com, and Time Domain Labs tools are for informational and educational purposes only. Not a medical device. Not FDA cleared or approved. No medical advice is provided.
We do not diagnose, treat, cure, or prevent any disease or medical condition. RMSSD, pNN50, and RR interval data are measures of autonomic activity, not a medical diagnosis.
Do not use this information to make medical decisions. Always consult a qualified healthcare professional for medical concerns. If you have a medical emergency, call 911.
You assume full responsibility for use of this site and its data.