What CSV data are needed for HRV analysis?
Chronological successive RR or accepted NN interval values with known units and enough information to assess missing data.
An HRV CSV file is useful only when you know what each column means. A spreadsheet of RR intervals can support RMSSD, SDNN and Poincaré analysis, but errors in units, timestamps, missing beats and filtering can invalidate the result.
This guide explains a reproducible workflow for reviewing interval exports. It does not claim that an HRV.live CSV upload tool is already available; the proposed /analyze page should only be promoted after it is built and tested.
A CSV may contain timestamps, BPM, RR intervals, device event codes and quality flags. Do not calculate RMSSD on the timestamp column or treat beats per minute as if it were milliseconds. RR values may be stored in seconds, milliseconds or Bluetooth 1/1024-second units. Confirm the format from the device or export documentation before converting.
For a quick formula check with a small set of interval values, use the existing RMSSD calculator. For live collection concepts, visit the HRV.live dashboard.
Before filtering, count all rows, valid intervals, missing entries and suspicious measurements. Look for duplicate timestamps, abrupt jumps, implausible values and long gaps. An unusual interval may reflect real physiology or a measurement error; an automatic threshold cannot always distinguish the two. Keep the unedited input and mark changes in a separate quality-control column.
If two different people apply different exclusion rules, their RMSSD results can diverge even on the same file. That is why a clean-data report should specify accepted intervals and the method used to decide whether each point was retained.
RMSSD is the root mean square of successive differences among accepted normal-to-normal intervals. SDNN is the standard deviation of those accepted intervals over the chosen window. pNN50 is the share of successive accepted differences exceeding 50 ms. A Poincaré graph pairs each interval with its successor and can help reveal unexpected patterns.
Document whether you used population or sample standard-deviation conventions and whether removed intervals broke the sequence into separate segments. Avoid treating distant intervals separated by missing data as adjacent unless the method explicitly accounts for the gap.
For resting comparisons, use the same duration, posture and processing method. If a file spans a breathing exercise or several activities, segment by the actual event times rather than averaging everything together. Record sensor type, software version, data length and the share of intervals excluded.
Research recommendations emphasize transparent artifact correction and reproducible reporting. This matters for individual comparisons too: a value is easier to trust when the same procedure was used on every date.
A helpful output summarizes measurement date, interval units, duration, number of original rows, accepted-beat count, exclusion proportion and chosen HRV metrics. It should explain how low-quality data were handled and include a warning against clinical interpretation. If plots are included, label axes and keep links to the original file.
For visual interpretation, use the Poincaré reading guide. For practical collection habits, consult the HRV measurement guide. Until a dedicated analysis endpoint is launched, these resources and the existing calculator are the verified tools.
Consider a file with timestamp_ms, rr_ms and quality_flag columns. Define timestamp_ms as the event time and rr_ms as the interval in milliseconds; do not subtract successive timestamps again if rr_ms is already the measured interval. Keep the unmodified file as an input artifact. Create a second table indicating which intervals are accepted, why any row was excluded and whether a gap interrupts consecutive pairing.
Calculate RMSSD on continuous accepted segments according to your declared rule, then report the recording window, interval count and percentage excluded. If the protocol changes, version it instead of rewriting old outputs without explanation. This approach makes a future web analyzer much easier to validate.
Chronological successive RR or accepted NN interval values with known units and enough information to assess missing data.
Average BPM alone does not preserve the beat-to-beat timing required for standard interval-based HRV metrics.
Do not delete blindly. Inspect the source, document an accepted correction method and retain the original data.
The proposed route did not resolve during this review; this article outlines the method rather than advertising a launched tool.
Reliable CSV analysis starts with correctly understood interval data and ends with a documented, reproducible calculation. A polished output is not evidence of quality unless the data trail is intact.
Explore the relevant tool: https://hrv.live/analyze
Educational information only. These tools do not diagnose, treat or rule out medical conditions. Consult a qualified healthcare professional for medical questions; seek urgent care for concerning symptoms.
Disclaimer
hrv.live, rmssd.com, and Time Domain Labs tools are for informational and educational purposes only. Not a medical device. Not FDA cleared or approved. No medical advice is provided.
We do not diagnose, treat, cure, or prevent any disease or medical condition. RMSSD, pNN50, and RR interval data are measures of autonomic activity, not a medical diagnosis.
Do not use this information to make medical decisions. Always consult a qualified healthcare professional for medical concerns. If you have a medical emergency, call 911.
You assume full responsibility for use of this site and its data.